MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1120700020971312

Медицинская библиотека · Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2020

Periprosthetic femoral fractures in sideways fall configuration: comparative numerical analysis of the influence of femoral stem design.

Franceschini Massimo, Barbera Luigi La, Anticonome Alberto, Ottardi Claudia, Tanaka Atsuki, Villa Tomaso

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The aim of this study was to investigate the mechanisms of periprosthetic fractures occurring as a result of a sideways fall in total hip arthroplasty patients, and to compare the predictions of numerical models in terms of load distribution on the implanted femur with clinical data.

MATERIALS AND

METHODS

3 numerical models were built: 1 for intact femur and 2 for implanted femur with a straight stem (resembling PBF, Permedica) and with an anatomical stem (resembling ABG II, Stryker). 4 loading configurations were simulated; 1 simulates a vertical load, and 3 simulate a fall with impact on the greater trochanter in different directions. Stress state calculated in the implanted femur was compared for the 2 models with reference to the intact case. These were compared with clinical data collected at a single centre (Istituto Ortopedico Gaetano Pini, Milan, Italy) where 41 patients were investigated after periprosthetic fracture: 26 patients had a straight uncemented stem and 15 an anatomical uncemented stem.

RESULTS

The maximum calculated strain in compression in the case of ABG II implanted femur was 2 times higher than in the presence of PBF stem in the vertical loading configuration. For configurations of sideways fall, in both models, there was a progressive increase of stress state in the bone with increasing angle. Simulations of sideways fall elicited results in accordance with clinical observations: due to the peculiar stem design and consequent state of stress in the bone, anatomical stems seem to induce trochanteric fractures more frequently, while for straight stems type B fractures are more likely to occur.

CONCLUSIONS

Clinical findings confirmed numerical model predictions: stem design seems to highly influence distribution of stress in the bone and consequent localisation of the fracture site.

Для цитирования: Franceschini Massimo, Barbera Luigi La, Anticonome Alberto, Ottardi Claudia, Tanaka Atsuki, Villa Tomaso. Periprosthetic femoral fractures in sideways fall configuration: comparative numerical analysis of the influence of femoral stem design.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2020. DOI: 10.1177/1120700020971312.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.