MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5371/hp.2014.26.3.166

Медицинская библиотека · Hip & pelvis · 2014

Treatment of Intertrochanteric Fractures Using the Compression Hip Nail.

Yi Je-Min, Han Kye Young, Kim Keun Woo, Ryu Chang Hyun

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the clinical and radiologic outcomes following treatment of intertrochanteric fractures using the Compression Hip Nail® (CHN), which has a sliding lag screw.

MATERIALS AND

METHODS

Twenty-eight cases of intertrochanteric fractures treated with CHN from November 2012 to October 2013 and followed-up for >6 months were included. The patient population consisted of 11 men and 17 women with a mean age of 75.2 years at the time of surgery. For the initial 11 cases, 10 mm sliding lag screws were used; the remaining 17 cases used 20 mm sliding lag screws. Clinical variables including operation time, amount of transfusion, weight-bearing start time, postoperative physical activity, and complications were investigated. The average sliding of lag screws and the average union were investigated radiologically at 3 and 6 months after surgery.

RESULTS

In an analysis of 23 cases (exclusion of 3 cases of lag screw cutout and 2 cases of nonunion), 11 (48%) recovered their pre-injury activity level. In an analysis of 25 cases (exclusion of 3 cases of cutout), 17 (68%) and 23 (92%) showed radiological union at postoperative months 3 and 6, respectively. Seven complications were noted. Cutout of the lag screw and the lateral protrusion of barrels were significantly greater in the group with 10 mm sliding lag screws as compared to the group using 20 mm sliding lag screws.

CONCLUSION

The use of CHN for the treatment of intertrochanteric fracture yielded poor results. However, results from patients in the 20 mm sliding lag screw group were better than for the 10 mm sliding lag screw group. Therefore, use of the 20 mm sliding lag screw is advisable.

Для цитирования: Yi Je-Min, Han Kye Young, Kim Keun Woo, Ryu Chang Hyun. Treatment of Intertrochanteric Fractures Using the Compression Hip Nail.. Hip & pelvis. 2014. DOI: 10.5371/hp.2014.26.3.166.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.