Determination of crystallinity and crystal structure of Hylamer polyethylene after in vivo wear.

Visentin M, Stea S, De Clerico M, Reggiani M, Fagnano C, Squarzoni S, Toni A

СтатьяПеревод в очереди

Аннотация

Hylamer polyethylene is a crystalline form of polyethylene of 70% crystallinity whereas conventional polyethylene (PE) has 50% crystallinity. Crystallinity is the percentage by weight of the crystalline phase present in the whole polymer, which comprises both amorphous and crystalline phases. Clinical experience has shown that Hylamer components used in joint prostheses, if sterilized by gamma rays in the presence of oxygen, are easily affected by wear, which leads to osteolysis. The authors have analyzed the crystallinity of polyethylene liners removed from seven patients who had received Hylamer polyethylene implants sterilized by gamma rays in air and had suffered prosthetic loosening, using Raman spectroscopy coupled with partial least squares (PLS) analysis. The results have been compared to those of two controls who had received Hylamer polyethylene implants sterilized by gamma irradiation in a nitrogen atmosphere. The crystal structure of wear particles released into the tissues from the Hylamer liners sterilized by gamma rays in air is also studied. The materials undergoing two different types of sterilization methods show different crystallinity values (71.50 vs. 69.43), but the crystallinity do not change according to wear (worn and unworn liner region). Both monoclinic and orthorhombic phases are present in the liner, while in wear debris prevalently monoclinic crystals are found in both types of sterilized liners. Different crystallinity rates can explain different wear rates observed in vivo.

Для цитирования: Visentin M, Stea S, De Clerico M, Reggiani M, Fagnano C, Squarzoni S, Toni A. Determination of crystallinity and crystal structure of Hylamer polyethylene after in vivo wear.. Journal of biomaterials applications. 2006. DOI: 10.1177/0885328206058786.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.