MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1503/cjs.010113

Медицинская библиотека · Canadian journal of surgery. Journal canadien de chirurgie · 2014

Low-intensity pulsed ultrasonography versus electrical stimulation for fracture healing: a systematic review and network meta-analysis.

Ebrahim Shanil, Mollon Brent, Bance Sheena, Busse Jason W, Bhandari Mohit

Сравнительное исследованиеСтатьяСистематический обзорNetwork Meta-AnalysisПеревод в очереди

Аннотация

BACKGROUND

To best inform evidence-based patient care, it is often desirable to compare competing therapies. We performed a network meta-analysis to indirectly compare low intensity pulsed ultrasonography (LIPUS) with electrical stimulation (ESTIM) for fracture healing.

METHODS

We searched the reference lists of recent reviews evaluating LIPUS and ESTIM that included studies published up to 2011 from 4 electronic databases. We updated the searches of all electronic databases up to April 2012. Eligible trials were those that included patients with a fresh fracture or an existing delayed union or nonunion who were randomized to LIPUS or ESTIM as well as a control group. Two pairs of reviewers, independently and in duplicate, screened titles and abstracts, reviewed the full text of potentially eligible articles, extracted data and assessed study quality. We used standard and network meta-analytic techniques to synthesize the data.

RESULTS

Of the 27 eligible trials, 15 provided data for our analyses. In patients with a fresh fracture, there was a suggested benefit of LIPUS at 6 months (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.97-1.41). In patients with an existing nonunion or delayed union, ESTIM had a suggested benefit over standard care on union rates at 3 months (RR 2.05, 95% CI 0.99-4.24). We found very low-quality evidence suggesting a potential benefit of LIPUS versus ESTIM in improving union rates at 6 months (RR 0.76, 95% CI 0.58-1.01) in fresh fracture populations.

CONCLUSION

To support our findings direct comparative trials with safeguards against bias assessing outcomes important to patients, such as functional recovery, are required.

Для цитирования: Ebrahim Shanil, Mollon Brent, Bance Sheena, Busse Jason W, Bhandari Mohit. Low-intensity pulsed ultrasonography versus electrical stimulation for fracture healing: a systematic review and network meta-analysis.. Canadian journal of surgery. Journal canadien de chirurgie. 2014. DOI: 10.1503/cjs.010113.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.