MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ijms21207438

Медицинская библиотека · International journal of molecular sciences · 2020

Investigation of Bone Growth in Additive-Manufactured Pedicle Screw Implant by Using Ti-6Al-4V and Bioactive Glass Powder Composite.

Lam Tu-Ngoc, Trinh Minh-Giam, Huang Chih-Chieh, Kung Pei-Ching, Huang Wei-Chin, Chang Wei, Amalia Lia, Chin Hsu-Hsuan, Tsou Nien-Ti, Shih Shao-Ju, Chen San-Yuan, Wang Chun-Chieh, Tsai Pei-I, Wu Meng-Huang, Huang E-Wen

СтатьяПеревод в очереди

Аннотация

In this study, we optimized the geometry and composition of additive-manufactured pedicle screws. Metal powders of titanium-aluminum-vanadium (Ti-6Al-4V) were mixed with reactive glass-ceramic biomaterials of bioactive glass (BG) powders. To optimize the geometry of pedicle screws, we applied a novel numerical approach to proposing the optimal shape of the healing chamber to promote biological healing. We examined the geometry and composition effects of pedicle screw implants on the interfacial autologous bone attachment and bone graft incorporation through in vivo studies. The addition of an optimal amount of BG to Ti-6Al-4V leads to a lower elastic modulus of the ceramic-metal composite material, effectively reducing the stress-shielding effects. Pedicle screw implants with optimal shape design and made of the composite material of Ti-6Al-4V doped with BG fabricated through additive manufacturing exhibit greater osseointegration and a more rapid bone volume fraction during the fracture healing process 120 days after implantation, per in vivo studies.

Для цитирования: Lam Tu-Ngoc, Trinh Minh-Giam, Huang Chih-Chieh, Kung Pei-Ching, Huang Wei-Chin, Chang Wei, Amalia Lia, Chin Hsu-Hsuan, Tsou Nien-Ti, Shih Shao-Ju, Chen San-Yuan, Wang Chun-Chieh, Tsai Pei-I, Wu Meng-Huang, Huang E-Wen. Investigation of Bone Growth in Additive-Manufactured Pedicle Screw Implant by Using Ti-6Al-4V and Bioactive Glass Powder Composite.. International journal of molecular sciences. 2020. DOI: 10.3390/ijms21207438.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.