MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.d.03039

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2005

Cemented rotating-platform total knee replacement. a concise follow-up, at a minimum of fifteen years, of a previous report.

Callaghan John J, O'Rourke Michael R, Iossi Michael F, Liu Steve S, Goetz Devon D, Vittetoe David A, Sullivan Patrick M, Johnston Richard C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We previously evaluated 119 consecutive total knee arthroplasties that were performed in eighty-six patients with use of the cemented LCS (low contact stress) rotating-platform system with an all-polyethylene patellar component. The average age of the patients at the time of surgery was seventy years (range, thirty-seven to eighty-eight years). The purpose of this study was to report the updated results at a minimum follow-up of fifteen years. Thirty-seven patients (fifty-three knees) were living, and no patient was lost to follow-up. No knee was revised because of loosening, osteolysis, or wear. Three knees required a reoperation (two for periprosthetic fractures and one for infection). No component was revised as a part of the reoperations. Osteolysis was present in three knees. No knee had radiographic signs of component loosening, and there were no dislocated bearings. The average range of motion was from 1 degrees of extension to 105 degrees of flexion. The average clinical and functional Knee Society scores were 43 and 49, respectively, at the preoperative evaluation and 85 and 58 at the time of the final follow-up. We concluded that the cemented LCS rotating-platform knee performed well, with durable clinical and radiographic results at a minimum follow-up of fifteen years.

Для цитирования: Callaghan John J, O'Rourke Michael R, Iossi Michael F, Liu Steve S, Goetz Devon D, Vittetoe David A, Sullivan Patrick M, Johnston Richard C. Cemented rotating-platform total knee replacement. a concise follow-up, at a minimum of fifteen years, of a previous report.. The Journal of bone and joint surgery. American volume. 2005. DOI: 10.2106/jbjs.d.03039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.