MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.d.02707

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2005

Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study.

Kim Young-Hoo, Sohn Keun-Soo, Kim Jun-Shik

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The restoration of posterior femoral translation has been shown to be an important factor in enhancing knee flexion after total knee arthroplasty. The purpose of this study was to compare the ranges of motion associated with standard and high-flexion posterior stabilized total knee prostheses in patients managed with simultaneous bilateral total knee arthroplasty.

METHODS

Fifty patients (mean age, sixty-eight years) received a standard fixed-bearing knee prosthesis in one knee and a high-flexion fixed-bearing knee prosthesis in the contralateral knee. Two patients were men, and forty-eight were women. At a mean of 2.1 years postoperatively, the patients were assessed clinically and radiographically with use of the knee-rating systems of the Knee Society and The Hospital for Special Surgery.

RESULTS

The mean postoperative Hospital for Special Surgery knee score was 90 points for the knees treated with the standard fixed-bearing prosthesis and 89.4 points for those treated with the high-flexion prosthesis. At the time of the final follow-up, the knees with the standard prosthesis had a mean range of motion of 135.8 degrees (range, 105 degrees to 150 degrees ) and those with a high-flexion prosthesis had a mean range of motion of 138.6 degrees (range, 105 degrees to 150 degrees ) (p = 0.41). No knee had aseptic loosening, revision, or osteolysis.

CONCLUSIONS

After a minimum duration of follow-up of two years, we found no significant differences between the groups with regard to range of motion or clinical and radiographic parameters, except for posterior femoral condylar offset.

Для цитирования: Kim Young-Hoo, Sohn Keun-Soo, Kim Jun-Shik. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study.. The Journal of bone and joint surgery. American volume. 2005. DOI: 10.2106/jbjs.d.02707.