MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-016-0744-4

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016

Evaluation of 68Ga-labeled peptide tracer for detection of gelatinase expression after myocardial infarction in rat.

Kiugel Max, Kytö Ville, Saanijoki Tiina, Liljenbäck Heidi, Metsälä Olli, Ståhle Mia, Tuomela Johanna, Li Xiang-Guo, Saukko Pekka, Knuuti Juhani, Roivainen Anne, Saraste Antti

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Matrix metalloproteinases 2 and 9 (MMP-2/9) play a role in extracellular matrix remodeling after an ischemic myocardial injury. We evaluated 68Ga-DOTA-peptide targeting MMP-2/9 for the detection of gelatinase expression after myocardial infarction (MI) in rat.

METHODS

Rats were injected with 43 ± 7.7 MBq of 68Ga-DOTA-peptide targeting MMP-2/9 at 7 days (n = 7) or 4 weeks (n = 8) after permanent coronary ligation or sham operation (n = 5 at both time points) followed by positron emission tomography (PET). The left ventricle was cut in frozen sections for autoradiography and immunohistochemistry 30 minutes after tracer injection.

RESULTS

Immunohistochemical staining showed MMP-2 and MMP-9 expressing cells, CD31-positive endothelial cells, and CD68-positive macrophages in the infarcted myocardium. Autoradiography showed increased tracer uptake in the infarcted area both at 7 days and 4 weeks after MI (MI-to-remote area ratio 2.5 ± 0.46 and 3.1 ± 1.0, respectively). Tracer uptake in damaged tissue correlated with the amount of CD68-positive macrophages at 7 days after MI, and CD31-positive endothelial cells at 7 days and 4 weeks after MI. The tracer was rapidly metabolized, radioactivity in the blood exceeded that of the myocardium, and tracer accumulation in the heart was not detectable by in vivo PET.

CONCLUSIONS

68Ga-DOTA-peptide targeting MMP-2/9 accumulates in the damaged rat myocardium after an ischemic injury, but tracer instability and slow clearance in vivo make it unsuitable for further evaluation.

Для цитирования: Kiugel Max, Kytö Ville, Saanijoki Tiina, Liljenbäck Heidi, Metsälä Olli, Ståhle Mia, Tuomela Johanna, Li Xiang-Guo, Saukko Pekka, Knuuti Juhani, Roivainen Anne, Saraste Antti. Evaluation of 68Ga-labeled peptide tracer for detection of gelatinase expression after myocardial infarction in rat.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2016. DOI: 10.1007/s12350-016-0744-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.