Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience.

Delgado Sánchez-Gracián Carlos, Oca Pernas Roque, Trinidad López Carmen, Santos Armentia Eloísa, Vaamonde Liste Antonio, Vázquez Caamaño María, Tardáguila de la Fuente Gonzalo

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine whether the quantification of iodine with stress dual-energy computed tomography (DECT-S) allows for the discrimination between a normal and an ischemic or necrotic myocardium using magnetic resonance (MR) as a reference.

METHODS

This retrospective study was approved by the institutional review board, with waiver of informed consent. Thirty-six cardiac MR and DECT-S images from patients with suspected coronary artery disease were evaluated. Perfusion defects were visually determined, and myocardial iodine concentration was calculated by two observers using DECT colour-coded iodine maps. Iodine concentration differences were calculated using parametric tests. Receiver operating characteristic (ROC) curve analysis was conducted to estimate the optimal iodine concentration threshold for discriminating pathologic myocardium.

RESULTS

In total, 576 cardiac segments were evaluated. There were differences in mean iodine concentration (p < 0.001) between normal (2.56 ± 0.66 mg/mL), ischemic (1.98 ± 0.36 mg/dL) and infarcted segments (1.35 ± 0.57 mg/mL). A myocardium iodine concentration of 2.1 mg/mL represented the optimal threshold to discriminate between normal and pathologic myocardium (sensitivity 75 %, specificity 73.6 %, area under the curve 0.806). Excellent agreement was found in measured myocardium iodine concentration (intraclass correlation coefficient 0.814).

CONCLUSION

Cardiac DECT-S with iodine quantification may be useful to differentiate healthy and ischemic or necrotic myocardium.

KEY POINTS: • DECT-S allows for determination of myocardial iodine concentration as a quantitative perfusion parameter. • A high interobserver correlation exists in measuring myocardial iodine concentration with DECT-S. • Myocardial iodine concentration may be useful in the assessment of patients with CAD.

Для цитирования: Delgado Sánchez-Gracián Carlos, Oca Pernas Roque, Trinidad López Carmen, Santos Armentia Eloísa, Vaamonde Liste Antonio, Vázquez Caamaño María, Tardáguila de la Fuente Gonzalo. Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience.. European radiology. 2015. DOI: 10.1007/s00330-015-4128-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.