The mean Hounsfield unit range acquired from different slices produces superior predictive accuracy for pyonephrosis in obstructive uropathy.

Huang Baoxing, Lu Guoliang, Zhao Yang, Tu Weichao, Shao Yuan, Wang Dawei, Xu Danfeng

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To determine the non-contrast computer tomography imaging features of pyonephrosis and evaluate the predictive value of Hounsfield units (HUs) in different hydronephrotic region slices.

MATERIALS AND

METHODS

We retrospectively reviewed data from patients with hydronephrosis who had renal-ureteral calculi. All patients were categorized into pyonephrosis and simple hydronephrosis groups. Baseline characteristics, the mean HU values in the maximal hydronephrotic region (uHU) slice, and the range of uHU in different slices (ΔuHU) were compared between the two groups. Univariate and multivariate analyses were performed to identify risk factors for pyonephrosis.

RESULTS

Among the 181 patients enrolled in the current study, 71 patients (39.2%) were diagnosed with pyonephrosis. The mean dilated pelvis surface areas were comparable between patients with pyonephrosis and simple hydronephrosis (822.61 mm² vs. 877.23 mm², p=0.722). Collecting system debris (p=0.022), a higher uHU (p=0.038), and a higher ΔuHU (p<0.001) were identified as independent risk factors for pyonephrosis based on multivariate analysis. The ΔuHU sensitivity and specificity were 88.7% and 86.4%, respectively, at a cutoff value of 6.56 (p<0.001), whereas the sensitivity and specificity for detecting pyonephrosis at a uHU cutoff value of 7.96 was 50.7% and 70.9%, respectively (p=0.003).

CONCLUSIONS

Non-contrast computer tomography was shown to accurately distinguish simple hydronephrosis from pyonephrosis in patients with obstructive uropathy. Evaluation of the ΔuHU in different slices may be more reliable than the uHU acquired from a single slice in predicting pyonephrosis.

Для цитирования: Huang Baoxing, Lu Guoliang, Zhao Yang, Tu Weichao, Shao Yuan, Wang Dawei, Xu Danfeng. The mean Hounsfield unit range acquired from different slices produces superior predictive accuracy for pyonephrosis in obstructive uropathy.. Investigative and clinical urology. 2024. DOI: 10.4111/icu.20230240.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.