Intra-operative electrooculographic monitoring to prevent post-operative extraocular motor nerve dysfunction during skull base surgeries.
Аннотация
BACKGROUND AND AIMS: Intra-operative identification and preservation of extraocular motor nerves is one of the main goals of surgeries for skull base tumours and this is done by monitoring the extraocular movement (EOM). Intra-operative electromyographic monitoring has been reported, but it is a complex and skilful process. Electrooculography (EOG) is a simple and reliable technique for monitoring EOMs. We aimed to assess the utility of EOG monitoring in preventing extraocular motor nerve dysfunction during skull base surgeries.
METHODS
In this retrospective cohort study, intra-operative EOG recordings were obtained using disposable needle electrodes placed on the periorbital skin and the polarity of the waves noted for interpretation. Triggered as well as continuous EOG responses were recorded after monopolar electrode stimulation of cranial nerve (CN) during tumour removal which helped the surgeon with careful dissection and avoiding potential nerve injuries.
RESULTS
Of the 11 cases monitored, oculomotor and abducent nerves were identified in all cases, but the trochlear nerve could not be definitively identified. Six patients had no pre- or post-operative extraocular motor nerve dysfunction. The other five patients had pre-existing deficits before surgery, which recovered completely in two, significantly in one, and did not improve in two patients at 3-6 months follow-up.
CONCLUSIONS
EOG was found to be a simple and reliable method of monitoring extraocular motor nerves (CNs III and VI) intraoperatively.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.