MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0177152

Медицинская библиотека · PloS one · 2017

Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial.

Gareb B, van Bakelen N B, Buijs G J, Jansma J, de Visscher J G A M, Hoppenreijs Th J M, Bergsma J E, van Minnen B, Stegenga B, Bos R R M

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Biodegradable fixation systems could reduce or eliminate problems associated with titanium removal of implants in a second operation.

AIM: The aim of this study was to compare the long-term (i.e. >5 years postoperatively) clinical performance of a titanium and a biodegradable system in oral and maxillofacial surgery.

MATERIALS AND

METHODS

The present multicenter Randomized Controlled Trial (RCT) was performed in four hospitals in the Netherlands. Patients treated with a bilateral sagittal split osteotomy (BSSO) and/or a Le Fort-I osteotomy, and those treated for fractures of the mandible, maxilla, or zygoma were included from December 2006 to July 2009. The patients were randomly assigned to either a titanium (KLS Martin) or a biodegradable group (Inion CPS).

RESULTS

After >5 years postoperatively, plate removal was performed in 22 of the 134 (16.4%) patients treated with titanium and in 23 of the 87 (26.4%) patients treated with the biodegradable system (P = 0.036, hazard ratio (HR) biodegradable (95% CI) = 2.0 (1.05-3.8), HR titanium = 1). Occlusion, VAS pain scores, and MFIQ showed good and (almost) pain free mandibular function in both groups.

CONCLUSION

In conclusion, the performance of the Inion CPS biodegradable system was inferior compared to the KLS Martin titanium system regarding plate/screws removal in the abovementioned surgical procedures.

TRIAL REGISTRATION: http://controlled-trials.com ISRCTN44212338.

Для цитирования: Gareb B, van Bakelen N B, Buijs G J, Jansma J, de Visscher J G A M, Hoppenreijs Th J M, Bergsma J E, van Minnen B, Stegenga B, Bos R R M. Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial.. PloS one. 2017. DOI: 10.1371/journal.pone.0177152.