MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1142/s2424835522500734

Медицинская библиотека · The journal of hand surgery Asian-Pacific volume · 2022

Cyclic Testing of a Modified Pull-Out Suture Repair Technique for Flexor Digitorum Profundus Avulsion in a Turkey Foot Model.

Sinclair Sonia, Clout Andrew, Peltz Tim S, Pelletier Matthew, Scougall Peter, Walsh William R

СтатьяПеревод в очереди

Аннотация

Background

Numerous repair techniques have been described for closed flexor digitorum profundus (FDP) avulsion. One option is a pull-out suture tied over the nail plate (Bunnell repair). We modified the Bunnell repair by incorporating a portion of the distal interphalangeal (DIP) joint volar plate into the repair to improve strength and reduce gapping. The aim of this study is to compare gap formation and load to failure between the Bunnell repair and our modification in a turkey foot model.

Methods

Twenty-four fresh-frozen cadaveric turkey feet were divided into two repair groups namely the conventional Bunnell pull-out suture technique and the modified Bunnell pull-out suture technique, incorporating the middle-third of the DIP joint volar plate into the repair. Both repairs were carried out with 3-0 prolene suture and underwent ex-vivo cyclic loading at 2-12 n in a sinusoidal wave for 100 cycles to simulate a passive range of motion (ROM) protocol. Subsequently, specimens were loaded to failure at 12 mm/minute. Gap formation and load to failure were measured.

Results

No repair ruptures occurred during cyclical testing. Mean gap formation was 9.2 mm (±1.49) in the Bunnell repair, and 3.5 mm (±1.19) in the modified Bunnell repair (p < 0.0001). The mean load to failure for the Bunnell repair was 35.4 n compared to 45 n for the modified repair (p = 0.0017).

Conclusions

Gap formation was reduced and load to failure increased by augmenting the Bunnell pull-out suture repair with the central portion of the DIP joint volar plate.

Для цитирования: Sinclair Sonia, Clout Andrew, Peltz Tim S, Pelletier Matthew, Scougall Peter, Walsh William R. Cyclic Testing of a Modified Pull-Out Suture Repair Technique for Flexor Digitorum Profundus Avulsion in a Turkey Foot Model.. The journal of hand surgery Asian-Pacific volume. 2022. DOI: 10.1142/s2424835522500734.