MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diagmicrobio.2025.116920

Медицинская библиотека · Diagnostic microbiology and infectious disease · 2025

Interlaboratory study to assess precision and reproducibility of the meningococcal antigen surface expression (MEASURE) assay to quantify factor H binding protein expression at the surface of meningococcal serogroup B strains.

Loschko Jakob, Liberator Paul, Findlow Jamie, Yip Jason, Tan Charles, Garcia Karen, Murillo MaryAnn, Gorantla Yamini, Moss Kimberly M, Maniatis Panagiotis, Clark Stephen A, Borrow Ray

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The serum bactericidal antibody using human complement (hSBA) assay, the accepted surrogate measure of meningococcal vaccine efficacy, is limited by human sera and complement requirements. Pfizer developed and validated the flow-cytometry-based Meningococcal Antigen Surface Expression (MEASURE) assay to quantify surface-expressed factor H binding protein (fHbp) levels on intact meningococci. Surface expression of fHbp is correlated with hSBA assay killing by MenB-fHbp (TrumenbaⓇ)-induced antibody, meaning the MEASURE assay can be used to predict meningococcal serogroup B (MenB) strain susceptibility to antibodies elicited by MenB-fHbp. This study aimed to evaluate interlaboratory precision and reproducibility of the MEASURE assay.

METHODS

The MEASURE assay was transferred to UK Health Security Agency (UKHSA) and US Centers for Disease Control and Prevention (CDC) laboratories. MEASURE assay results from 42 MenB strains encoding sequence-diverse fHbp variants that express fHbp at different levels were compared between the UKHSA, CDC, and Pfizer laboratories. Intermediate precision within each laboratory was determined.

RESULTS

Pairwise comparisons of fHbp expression levels for all 42 MenB test strains showed >97 % agreement across the 3 laboratories when strains were grouped above or below a mean fluorescence intensity level of 1000, the threshold previously established as indicative of susceptibility to MenB-fHbp-induced antibodies in the hSBA assay. Each laboratory met assay precision criteria of ≤30 % total relative standard deviation.

CONCLUSIONS

Quantification of fHbp surface expression using the MEASURE assay is robust and reproducible across different laboratories. Previously determined cutoffs corresponding to predicted susceptibility to vaccine-induced antibodies can be applied to MEASURE data generated across laboratories.

Для цитирования: Loschko Jakob, Liberator Paul, Findlow Jamie, Yip Jason, Tan Charles, Garcia Karen, Murillo MaryAnn, Gorantla Yamini, Moss Kimberly M, Maniatis Panagiotis, Clark Stephen A, Borrow Ray. Interlaboratory study to assess precision and reproducibility of the meningococcal antigen surface expression (MEASURE) assay to quantify factor H binding protein expression at the surface of meningococcal serogroup B strains.. Diagnostic microbiology and infectious disease. 2025. DOI: 10.1016/j.diagmicrobio.2025.116920.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.