MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/scs.0000000000011108

Медицинская библиотека · The Journal of craniofacial surgery · 2025

Prognostics Factors to Avoid Eye Injuries in Angle Grinders.

Ke Wang, Gu Kaiming, Zhu Suhui, Wu Jianhao, Dai Yan

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To analyze the clinical characteristics and prognostic factors of eye injuries caused by angle grinders over 2 years.

METHODS

Clinical data from 36 hospitalized patients (36 eyes) with eye injuries caused by angle grinders were collected. The causes of injury, types of trauma, and prognoses were analyzed.

RESULTS

Among the 36 patients (36 eyes), 34 were male (34 eyes) and 2 were female (2 eyes), with ages ranging from 19 to 66 years. The time from injury to medical consultation was within 12 hours in 29 cases, between 12 and 24 hours in 6 cases, and over 24 hours in 1 case. Primary emergency globe repair surgery was performed within 8 hours of admission in 23 cases, while 29 cases required secondary surgical interventions. Preoperative visual acuity was recorded as no light perception to 0.05 in 13 cases, 0.05 to 0.1 in 10 cases, 0.1 to 0.3 in 9 cases, and >0.3 in 4 cases. Postoperative best-corrected visual acuity was <0.05 in 10 cases, 0.05 to 0.1 in 13 cases, 0.1 to 0.3 in 7 cases, and >0.3 in 6 cases.

CONCLUSION

Eye injuries caused by angle grinders are often complex, involving both ocular adnexa and globe injuries, with multiple sites of intraocular trauma. A high proportion of patients require secondary surgical interventions. Factors affecting visual outcomes include the location and type of injury, time to medical consultation, presence of infectious endophthalmitis, and intraocular foreign bodies.

Для цитирования: Ke Wang, Gu Kaiming, Zhu Suhui, Wu Jianhao, Dai Yan. Prognostics Factors to Avoid Eye Injuries in Angle Grinders.. The Journal of craniofacial surgery. 2025. DOI: 10.1097/scs.0000000000011108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.