MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40635-023-00516-4

Медицинская библиотека · Intensive care medicine experimental · 2023

In an endotoxaemic model, antibiotic clearance can be affected by different central venous catheter positions, during renal replacement therapy.

Bandert Anna, Lipcsey Miklós, Frithiof Robert, Larsson Anders, Smekal David

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In intensive care, different central venous catheters (CVC) are often used for infusion of drugs. If a patient is treated with continuous renal replacement therapy (CRRT) a second catheter, a central venous dialysis catheter (CVDC), is needed. Placing the catheters close together might pose a risk that a drug infused in a CVC could be directly aspirated into a CRRT machine and cleared from the blood without giving the effect intended. The purpose of this study was to elucidate if drug clearance is affected by different catheter placement, during CRRT. In this endotoxaemic animal model, an infusion of antibiotics was administered in a CVC placed in the external jugular vein (EJV). Antibiotic clearance was compared, whether CRRT was through a CVDC placed in the same EJV, or in a femoral vein (FV). To reach a target mean arterial pressure (MAP), noradrenaline was infused through the CVC and the dose was compared between the CDVDs.

RESULTS

The main finding in this study was that clearance of antibiotics was higher when both catheter tips were in the EJV, close together, compared to in different vessels, during CRRT. The clearance of gentamicin was 21.0 ± 7.3 vs 15.5 ± 4.2 mL/min (p 0.006) and vancomycin 19.3 ± 4.9 vs 15.8 ± 7.1 mL/min (p 0.021). The noradrenaline dose to maintain a target MAP also showed greater variance with both catheters in the EJV, compared to when catheters were placed in different vessels.

CONCLUSION

The results in this study indicate that close placement of central venous catheter tips could lead to unreliable drug concentration, due to direct aspiration, during CRRT.

Для цитирования: Bandert Anna, Lipcsey Miklós, Frithiof Robert, Larsson Anders, Smekal David. In an endotoxaemic model, antibiotic clearance can be affected by different central venous catheter positions, during renal replacement therapy.. Intensive care medicine experimental. 2023. DOI: 10.1186/s40635-023-00516-4.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.