MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.vaccine.2024.126508

Медицинская библиотека · Vaccine · 2024

Development and validation of a standardized human complement serum bactericidal activity assay to measure functional antibody responses to Neisseria gonorrhoeae.

Matthias Kathryn A, Reveille Alexandra, Dhara Kumaresh, Lyle Christopher S, Natuk Robert J, Bonk Brian, Bash Margaret C

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

The recent entry of multiple vaccines targeting Neisseria gonorrhoeae (Ng) into the clinical development pathway has highlighted the need to establish methods of adequately assessing anti-gonococcal immune responses. Serum bactericidal activity (SBA) is utilized as a measurement of efficacy in licensure of meningococcal vaccines, but the importance of functional antibodies in preventing and/or clearing gonococcal infections remains largely unknown. In an effort to elucidate the utility of SBA as an immune correlate of protection, we sought to develop a standardized high-throughput human complement SBA (hSBA) assay for which any strain of interest could be tested under uniform conditions, with minimal screening of complement required. Utilization of IgG/IgM-depleted pooled human complement serum permitted testing of diverse serum resistant and sensitive gonococcal and unencapsulated meningococcal strains when bacteria were cultured to induce lipooligosaccharide sialylation; only one of nine randomly selected lots demonstrated intrinsic toxicity. The hSBA assay was well suited for use with multiple test serum sources, including rabbit, mouse, and human serum samples, suggesting widespread applicability.

Для цитирования: Matthias Kathryn A, Reveille Alexandra, Dhara Kumaresh, Lyle Christopher S, Natuk Robert J, Bonk Brian, Bash Margaret C. Development and validation of a standardized human complement serum bactericidal activity assay to measure functional antibody responses to Neisseria gonorrhoeae.. Vaccine. 2024. DOI: 10.1016/j.vaccine.2024.126508.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.