The reproducibility of urodynamic studies of neurogenic bladders in spinal cord injury.

Ho C H, Linsenmeyer T A, Millis S R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the reproducibility (test-retest reliability) of urodynamic studies in neurogenic bladders of subjects with spinal cord injuries (SCI).

DESIGN

Retrospective case series.

SETTING

Urology department of a major rehabilitation center.

SUBJECTS: Fifty individuals with SCI who had urodynamic studies performed from February 2000 to April 2000.

MAIN OUTCOME MEASURES: Two trials (Time 1 and Time 2) of urodynamic studies done 5 minutes apart, with the following collected: bladder volume at first sensation, maximum cystometric capacity, presence of uninhibited contractions, opening pressure, maximum detrusor pressure, duration of bladder contraction, volume voided, and post-void residual (PVR) volume. The corresponding data were then compared. Statistical analysis was performed using the Lin's concordance correlation coefficient and kappa.

RESULTS

Analysis of the data showed statistically significant levels of agreement between Time 1 and Time 2 with regard to the various corresponding parameters for both the filling and voiding phases. For 3 of the most important parameters-the opening pressure, maximum detrusor pressure, and duration of contraction-the Lin's concordance correlation coefficient (r(c)) was .86 (95% CI, .78-.95; p < .0005), .91 (95% CI, .86-.96; p < .0005), and .97 (95% CI, .95-.99, p < .0005), respectively.

CONCLUSION

The study demonstrates good short-term intrasubject reproducibility of urodynamic studies in individuals with SCI.

Для цитирования: Ho C H, Linsenmeyer T A, Millis S R. The reproducibility of urodynamic studies of neurogenic bladders in spinal cord injury.. The journal of spinal cord medicine. 2000. DOI: 10.1080/10790268.2000.11753537.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.