MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4111/icu.20200276

Медицинская библиотека · Investigative and clinical urology · 2021

Efficacy and safety of modified tract dilation technique using simultaneous pulling of proximal and distal ends of a guidewire for percutaneous nephrolithotomy in modified supine position.

Chung Jae Wook, Ha Heon, Park Dong Jin, Ha Yun Sok, Lee Jun Nyung, Chun So Young, Kwon Tae Gyun, Kim Bum Soo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Recently, the needs for supine percutaneous nephrolithotomy (PCNL) have become more increased because of an easy approach for endoscopic combined intrarenal surgery. However, making a nephrostomy tract during supine PCNL is more difficult than prone position due to movable kidney. To overcome this limitation, we used a modified nephrostomy tract dilation (MTD) technique using guidewire traction.

MATERIALS AND

METHODS

From January 2014 to June 2019, a total of 259 patients underwent PCNL in the modified supine position. Among them, the MTD technique was performed in 171 patients. For the MTD technique, two hydrophilic guidewires were passed from the nephrostomy tract and brought out through the urethra, then both proximal and distal ends were contralaterally pulled with tension for the easy placement of a fascia-cutting needle and a balloon catheter. We analyzed the efficacy of this technique in comparison with the conventional method.

RESULTS

Intraoperative radiation exposure time (RET) (68.87 vs. 212.11 s) and hospital stay (5.90 vs. 6.74 days) were significantly shorter, while the success rate (77.2% vs. 63.6%) was significantly higher in the MTD group. Multivariate analysis showed that only the maximal stone diameter (odds ratio [OR], 1.928; 95% confidence interval [CI], 1.314-2.828; p=0.001) and MTD technique (OR, 0.017; 95% CI, 0.007-0.040; p<0.001) were independent factors for predicting short RET (<120 s).

CONCLUSIONS

This study demonstrated that MTD technique can be effectively and safely performed in modified supine position PCNL, and it can be helpful in reducing RET and enhancing success rates.

Для цитирования: Chung Jae Wook, Ha Heon, Park Dong Jin, Ha Yun Sok, Lee Jun Nyung, Chun So Young, Kwon Tae Gyun, Kim Bum Soo. Efficacy and safety of modified tract dilation technique using simultaneous pulling of proximal and distal ends of a guidewire for percutaneous nephrolithotomy in modified supine position.. Investigative and clinical urology. 2021. DOI: 10.4111/icu.20200276.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.