MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s133938

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2017

Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer.

Sandinha Maria T, Kotagiri Ajay K, Owen Rona I, Geenen Caspar, Steel David Hw

СтатьяПеревод в очереди

Аннотация

PURPOSE: To assess the accuracy of B-scan ultrasound (U/S) in diagnosing cases of acute fundus obscuring vitreous hemorrhage (FOVH) using a standardized scan protocol and dedicated ophthalmic ultrasonographer.

METHODS

Consecutive patients presenting with acute FOVH of unknown cause, between January 2013 and December 2014, were prospectively recruited. Patients underwent a scan performed by a dedicated ultrasonographer, utilizing a systematic scan sequence and using an ocular specific U/S device. The U/S findings were compared to the findings during vitrectomy or after spontaneous hemorrhage clearance.

RESULTS

Fifty-eight eyes (58 patients) were included. An underlying rhegmatogenous retinal detachment (RRD) and retinal tears without RRD were reported in nine and 14 patients, respectively. Nineteen of these patients underwent vitrectomy, and the other four underwent laser retinopexy or cryopexy alone. An additional six patients with suspected but uncertain retinal tears underwent vitrectomy, during which tears were confirmed in three, two had retinal vessel avulsions, and one had retinal new vessels. There was "complete" agreement between the B-scan findings and clinical findings in 78% of patients, "partial" agreement in 19%, and agreement was not tested in 3%. When the agreement was "partial", the disagreements did not affect patient management. The sensitivity was 100% for the detection of RRD, and for the detection of new retinal tears in patients without retinal detachment.

CONCLUSION

B-scan U/S scan was highly sensitive in identifying the pathology in acute FOVH. Our results show an improvement from previously reported results, likely related to the standardized scan protocol and dedicated ophthalmic ultrasonographer.

Для цитирования: Sandinha Maria T, Kotagiri Ajay K, Owen Rona I, Geenen Caspar, Steel David Hw. Accuracy of B-scan ultrasonography in acute fundus obscuring vitreous hemorrhage using a standardized scanning protocol and a dedicated ophthalmic ultrasonographer.. Clinical ophthalmology (Auckland, N.Z.). 2017. DOI: 10.2147/opth.s133938.