Use of the Surfacer® Inside-Out® Catheter Access System to Obtain Central Venous Access in Dialysis Patients With Thoracic Venous Obstructions: Single-Center Series.

Galas Noemi, Shahverdyan Robert

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Thoracic central venous obstruction (TCVO) is a common condition which can impact the ability to achieve central venous access (CVA) in patients on hemodialysis. The Surfacer® Inside-Out® Catheter Access System is designed to enable repeated right-side central venous access in patients with TCVO.

METHODS

We retrospectively analyzed medical records of 10 dialysis patients who presented with TCVO and underwent the Inside-Out procedure with the Surfacer System to obtain CVA between 2017 and 2020. Patient demographics, hemodialysis vascular access history, and procedural data were identified and analyzed. The mean patient age was 62.4 ± 19.6 years (25.9-89.1 years) with 7 of the 10 patients being male. Eight patients (80.0%) were diagnosed with chronic kidney disease with time on hemodialysis ranging from 3 to 13 years. The remaining 2 required CVA to treat acute-on-chronic kidney injury due to septic shock. Patients in our series had a mean of 2.8 ± 1.6 previous catheters placed prior to the Surfacer procedure.

RESULTS

CVA was achieved in all 10 patients with 1 patient requiring a second attempt to achieve access due to the inability to initially traverse the iliac vein with the device, possibly due to a history of kidney transplantation. One multimorbid patient died shortly after the successful procedure, possibly due to cardiac decompensation. Mean total procedure time for the 7 patients having only dialysis catheter placement using the Surfacer device was 67.2 ± 19.1 minutes (49-103 minutes). The remaining 3 patients received a Hemodialysis Reliable Outflow (HeRO) graft in conjunction with the Inside-Out procedure. All vascular accesses functioned properly during the immediate time period following placement. No adverse events associated with the use of Surfacer device were encountered.

CONCLUSIONS

Data presented from our patient series confirms the effectiveness of the Surfacer System to safely achieve CVA in dialysis patients with TCVOs with a history of multiple catheter placements.

Для цитирования: Galas Noemi, Shahverdyan Robert. Use of the Surfacer® Inside-Out® Catheter Access System to Obtain Central Venous Access in Dialysis Patients With Thoracic Venous Obstructions: Single-Center Series.. Vascular and endovascular surgery. 2020. DOI: 10.1177/1538574420980604.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.