MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.70370

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025

Simultaneous Repair of Iatrogenic Left Atrial and Aortic Perforations Using Ductus Arteriosus Occluders: A Case Report.

Wu Zhihao, Ouyang Shumin, Liao Minqi, Chen Lihua, Yin Haixian, Zhou Jianping, Guo Suxia

Клинический случайСтатьяПеревод в очереди

Аннотация

Iatrogenic perforation of the left atrium and aorta during transseptal puncture (TSP) is a rare but potentially life-threatening complication. This report presents the case of an elderly male patient with a 20-year history of atrial fibrillation who experienced this complication during a scheduled left atrial appendage closure procedure. During the procedure, the sheath inadvertently penetrated the left atrial wall and mediastinal tissues, resulting in perforation of the descending aorta. To prevent hemorrhage and secondary injury, we successfully repaired the defects by simultaneously deploying two ductus arteriosus occluders through the original access tract. Immediate post-procedural and 1-month follow-up assessments confirmed stable device position with no residual shunt, pericardial effusion, or thromboembolic complications. This case represents the first documented instance of concurrent closure of both left atrial and descending aortic perforations using ductus arteriosus occluders. It highlights the critical importance of prompt intervention for complex cardiac complications and demonstrates the feasibility of dual-chamber repair using occluder devices.

Для цитирования: Wu Zhihao, Ouyang Shumin, Liao Minqi, Chen Lihua, Yin Haixian, Zhou Jianping, Guo Suxia. Simultaneous Repair of Iatrogenic Left Atrial and Aortic Perforations Using Ductus Arteriosus Occluders: A Case Report.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2025. DOI: 10.1002/ccd.70370.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.