DOI 10.1016/j.joms.2020.09.038
Finite Element Analysis of Different Titanium Plates for Internal Fixation of Fractures of the Mandibular Condylar Neck.
Аннотация
PURPOSE: The purpose of the present study is to compare the performance of 4 titanium miniplates (alpha, kappa, rhomboidal, and trapezoidal) used for the fixation of condylar neck fractures by implementing computational finite element analysis.
METHODS
Three-dimensional models of the plates were used to reduce a virtually created condylar neck fracture in a mandible obtained from a computed tomography scan of a healthy adult. The developed models were analyzed, making use of the finite element method under 2 loading scenarios: a reduced postoperative bite force of 135 N and a clenching force of 500 N were examined. The plating designs' performance was assessed based on displacements along the fracture area, bone strains, and plate stresses.
RESULTS
For a loading limited to 135 N, all 4 plates offer an adequate fixation with a small risk of screw loosening for the rhomboidal and trapezoidal plates. For an applied force of 500 N, the alpha and kappa plates showed better results, distributing more homogeneously the strains in the bone and offering better rigidity.
CONCLUSIONS
These findings implicate that the alpha and kappa plates performed better when bigger loads are applied. On the other hand, the trapezoidal and rhomboidal plates are not recommended for condylar fractures, especially if bigger functional loads are expected.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.