DOI 10.1097/ta.0000000000003894
REBOA for the Treatment of Blast Polytrauma: Zone 3 Provides Cerebral Perfusion, Attenuates Organ Dysfunction and Reperfusion Coagulopathy Compared to Zone 1 in a Swine Model.
Аннотация
BACKGROUND
Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a lifesaving therapy for hemorrhagic shock following pelvic/lower extremity injuries in military settings. However, Zone 1 aortic occlusion (AO; above the celiac artery), while providing brain/cardiac perfusion, may induce/worsen visceral ischemia and organ dysfunction. In contrast, AO Zone 3 (below the renal arteries) provides abdominal perfusion potentially minimizing ischemia/reperfusion injury. We hypothesized that, compared with AO Zone 1, AO Zone 3 provides neuro/cardioprotection while minimizing visceral ischemia and reperfusion coagulopathy after severe traumatic hemorrhage due to pelvic/lower extremity injuries.
METHODS
Fifty-kilogram male Yorkshire swine underwent a blast polytrauma injury followed by a resuscitation protocol with randomization to no AO (No AO, n = 6) or AO with REBOA at Zone 1 (AO Zone 1; n = 6) or Zone 3 (AO Zone 3; n = 4). Vital signs and intracranial pressure (ICP) were monitored for 240 minutes. Citrate native and tissue plasminogen activator challenge thrombelastography, prothrombin time, creatinine, lipase, total bilirubin, troponin, and enzyme-linked immunosorbent assays protein levels were measured at set intervals.
RESULTS
Both AO groups had significant increases in mean arterial pressure during aortic occlusion. All three groups had significant increases in ICP, but final ICP in the No AO group (26 ± 5.8 mm Hg) was significantly elevated compared with AO Zone 1 (17 ± 5.2 mm Hg) and AO Zone 3 (16 ± 4.2 mm Hg) ( p < 0.01). The final mean troponin in the No AO group (4.10 ± 5.67 ng/mL) was significantly higher than baseline (0.03 ± 0.02 ng/mL, p < 0.05), while the two AO groups had no significant changes ( p > 0.05). AO Zone 1 was the only group associated with hyperfibrinolysis ( p < 0.05) and significantly increased prothrombin time ( p < 0.05). Only AO Zone 1 group had significantly higher markers of organ damage.
CONCLUSION
Compared with AO Zone 1, AO Zone 3 provided similar neuro/cardioprotection but with less organ dysfunction and coagulopathy. This study suggests that Zone 3 REBOA may be preferable over Zone 1 for treating military relevant blast polytrauma with minimal intra-abdominal and chest trauma, but further clinical investigation is warranted.