MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ab.2023.115363

Медицинская библиотека · Analytical biochemistry · 2023

Acid hydrolysis conditions for quantification of meningococcal X polysaccharide in a pentavalent vaccine using HPAEC-PAD/ESI-MS.

Ghosh Saurav, Pawar Rakesh, Kangralkar Vivek, Mallya Asha D, Dhere Rajeev M, Bolgiano Barbara, Ravenscroft Neil

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A selective and sensitive method was evaluated for quantitation of meningococcal X (Men X) polysaccharide in pentavalent meningococcal A, C, W, Y and X conjugate vaccine using different acid hydrolysis conditions like HCl, TFA, HF, HF-TFA, and HF-HCl. High-performance anion exchange chromatography with pulsed amperometric detection (HPAEC-PAD) using CarboPac PA10 column was used to identify the hydrolyzed products based on retention time and its comparison with monosaccharide standards. Complete release of glucosamine (GlcN) from Men X in monovalent bulk and pentavalent vaccine samples was achieved using HF hydrolysis at 80 °C for 2 h. The Men X HF-hydrolyzed polysaccharide to glucosamine along with the reference standard was identified using collision-induced dissociation (CID) electrospray mass spectroscopy and the MS/MS fragments of m/z 162, m/z 144 and m/z 84. Meningococcal polysaccharide concentration was determined with a correlation coefficient r2 >0.99 using polysaccharide reference standard. The serogroups A, W, and Y were converted to their monosaccharides units and quantified using this method however, milder acid hydrolysis 0.1 M HCl 80 °C 2 h for release of sialic acid for Men C polysaccharide was found to be more suitable. These methods will provide necessary tools and prove to be beneficial to laboratories developing new saccharide-based vaccine combinations.

Для цитирования: Ghosh Saurav, Pawar Rakesh, Kangralkar Vivek, Mallya Asha D, Dhere Rajeev M, Bolgiano Barbara, Ravenscroft Neil. Acid hydrolysis conditions for quantification of meningococcal X polysaccharide in a pentavalent vaccine using HPAEC-PAD/ESI-MS.. Analytical biochemistry. 2023. DOI: 10.1016/j.ab.2023.115363.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.