MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1536/ihj.24-544

Медицинская библиотека · International heart journal · 2025

Recurrent Cardiac Tamponade Following Rotablator-Associated Coronary Perforation Treated with Additional Covered Stent Implantation.

Hori Koichiro, Matsuno Shunsuke, Kishi Mikio, Kano Hiroto, Yajima Junji, Oikawa Yuji

СтатьяКлинический случайПеревод в очереди

Аннотация

Rotablator-associated coronary perforation can be fatal if bailout is delayed. Successful bailout is typically defined as the disappearance of contrast extravasation after a haemostatic intervention. We report a case of recurrent cardiac tamponade in the subacute phase, wherein haemostasis appeared to have been achieved on angiography following the implantation of a covered stent during the index procedure.A 61-year-old male underwent a percutaneous coronary intervention with a rotator placed in the middle of the left ascending artery. Coronary perforation occurred during rotablation and was treated with a covered stent. However, cardiac tamponade recurred on postoperative day 30. Emergency coronary angiography was performed, and no contrast extravasation was observed on angiography. However, intravascular ultrasonography was performed to clarify the cause of the recurrent pericardial effusion and revealed that the distal edge of the covered stent was not fully attached to the vessel wall due to protruding calcification. Another covered stent was placed distal to the previous stent for sealing the malapposed site. There was no recurrence of pericardial effusion.Malapposition of covered stents may not be detected by angiography alone, potentially resulting in recurrent bleeding. Intravascular imaging is an effective tool to confirm adequate stent apposition.

Для цитирования: Hori Koichiro, Matsuno Shunsuke, Kishi Mikio, Kano Hiroto, Yajima Junji, Oikawa Yuji. Recurrent Cardiac Tamponade Following Rotablator-Associated Coronary Perforation Treated with Additional Covered Stent Implantation.. International heart journal. 2025. DOI: 10.1536/ihj.24-544.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.