MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jneumeth.2026.110872

Медицинская библиотека · Journal of neuroscience methods · 2026

A reproducible rat model of microembolic brain injury using percutaneous coaxial microcatheter delivery of zirconia beads.

Kasa Kentaro, Ohta Hiroki, Komatsu Teppei, Yoshioka Misato, Kejia Dai, Koizumi Makoto, Ohki Takao, Okano Hirotaka James

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cerebral microembolism contributes to silent brain infarction and procedure-related ischemic brain injury during catheter-based endovascular interventions. However, reproducible experimental platforms simulating particulate embolization under endovascular conditions remain limited.

NEW METHOD: We developed a rat model of microembolic brain injury using percutaneous coaxial microcatheter delivery of zirconia beads under fluoroscopic guidance. Zirconia beads (15 µm) were loaded as a sedimented column in iodinated contrast medium within an inner microcatheter, advanced coaxially through an outer microcatheter, and delivered selectively to the left internal carotid artery (ICA) territory via the caudal ventral artery. Animals with an ICA curvature angle > 40° were excluded to reduce procedure-related variability.

RESULTS

Among 25 male Sprague-Dawley rats, three were excluded before embolization because of unfavorable anatomy, leaving 18 embolized rats and four sham-operated controls for analysis. The median operative time was 8.5 min (IQR, 6.3-11.0). No procedure-related mortality or significant vasospasm occurred. TTC staining at 24 h demonstrated ipsilateral infarcts in all embolized animals, with a median infarct volume of 18.7 mm³ (IQR, 15.8-24.7). No infarct lesions were observed in sham-operated animals. Infarct volume was not significantly correlated with neurological deficit score.

COMPARISON WITH EXISTING

METHODS

Unlike conventional microsphere- or thrombus-based embolic models that typically require cervical vessel exposure and direct arterial injection, this method enables minimally invasive, fluoroscopy-guided, selective embolic delivery with angiographic monitoring and dose standardization based on catheter geometry and sediment length.

CONCLUSIONS

This model provides a reproducible translational platform for studying microembolic brain injury and evaluating preventive or therapeutic strategies.

Для цитирования: Kasa Kentaro, Ohta Hiroki, Komatsu Teppei, Yoshioka Misato, Kejia Dai, Koizumi Makoto, Ohki Takao, Okano Hirotaka James. A reproducible rat model of microembolic brain injury using percutaneous coaxial microcatheter delivery of zirconia beads.. Journal of neuroscience methods. 2026. DOI: 10.1016/j.jneumeth.2026.110872.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.