MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-010-1119-y

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2010

Problems of bridging plate fixation for the treatment of forearm shaft fractures with the locking compression plate.

Henle Philipp, Ortlieb Kevin, Kuminack Kerstin, Mueller Christof A, Suedkamp Norbert P

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Treatment of diaphyseal forearm fractures by open reduction and internal plate fixation is a well-accepted strategy. In a variety of fracture localizations, the use of bridging plate fixation with locking compression plates (LCP) has been shown to improve biomechanical and biological characteristics. Only very limited clinical data are available on bridging plate fixation using LCPs for the treatment of diaphyseal forearm fractures. The aims of this study were to assess both clinical outcomes of LCP fracture treatments, and the implant-specific advantages and disadvantages.

METHOD: The study consisted of 53 patients. All relevant data were extracted from the medical reports and radiographs. Of the 53 patients, 39 completed the disabilities of the arm, shoulder and hand (DASH) questionnaire and 35 patients were available for clinical examination. The mean time of follow-up was 23.3 months.

RESULTS

Thirty-nine fractures of the radius and 45 fractures of the ulna were treated with 3.5 mm LCPs. Due to a fracture non-union, four patients underwent a second operation. In 13 patients, hardware had already been removed at the time of follow-up. Complete documentation of the removal operation was available for ten patients; in seven of these, procedures difficulties occurred. Mean ranges of motion were 138°, 141° and 162° for elbow flexion-extension, wrist flexion-extension and pronation-supination, respectively. The mean DASH score was calculated at 14.9.

CONCLUSION

In conclusion, our data show that clinical and functional outcomes of LCP plating of diaphyseal forearm fractures are comparable to the use of conventional implants. However, implant-specific problems during hardware removal must be considered.

Для цитирования: Henle Philipp, Ortlieb Kevin, Kuminack Kerstin, Mueller Christof A, Suedkamp Norbert P. Problems of bridging plate fixation for the treatment of forearm shaft fractures with the locking compression plate.. Archives of orthopaedic and trauma surgery. 2010. DOI: 10.1007/s00402-010-1119-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.