MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iop.0000000000002480

Медицинская библиотека · Ophthalmic plastic and reconstructive surgery · 2023

Structural Limits of Orbital Compliance and Treatment Options for Pathologic Orbital Pressure.

Chelnis James, Kim Juliet, Meador Andrew, Oester Alan E, Fleming James C, Fowler Brian T

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The integrity of the orbit has a finite structural limit due to the compliance of its tissue. The authors investigate these limits to quantify them and inform the treatment of heightened ocular and orbital pressure.

METHODS

Cadaveric study with 12 orbits being volumized before randomization of treatment for pathologic levels of ocular and orbital pressure. First-line and second-line treatment was chosen randomly (lateral cantholysis, superior septolysis, inferior septolysis). Prior to treatment, IOP, orbital compartment pressure, and axial globe projection was measured after delivery of each 1cc aliquot and surgical treatment.

RESULTS

Orbital compartment pressure and IOP were well correlated (r = 0.99). The average reduction in IOP after treatment averaged a 56.2 mm Hg reduction in IOP. All treatments were statistically equivalent ( p < 0.01). Loss of compliance (P LOC ) was determined when the mean plus 1 standard deviation of change in IOP/ml volume was achieved with simultaneous change in exophthalmometry of <0.5 mm change/ml added volume, indicating an acceleration in pressure in the face of a steady volume. This criteria was met for 11 of 12 orbits. The 12th orbit missed this threshold by 1 mm Hg in IOP. P LOC occurred at an average IOP of 43.0 mm Hg (±5.8 mm Hg, 90% CI) and after an average injection of 13 ml (±1.4 mm, 90% CI). Additionally, lateral cantholysis, superior septolysis, and inferior septolysis were statistically equivalent in reducing IOP after P LOC .

CONCLUSIONS

IOP and orbital compartment pressure are excellent proxies for each other in the authors' model. Orbital compliance is a mathematic phenomenon that can be quantified, as evident in this investigation. P LOC can inform timing for orbital decompressions in the presence of heightened IOP. Multiple procedures can be used to extinguish dangerously high orbital compartment pressure.

Для цитирования: Chelnis James, Kim Juliet, Meador Andrew, Oester Alan E, Fleming James C, Fowler Brian T. Structural Limits of Orbital Compliance and Treatment Options for Pathologic Orbital Pressure.. Ophthalmic plastic and reconstructive surgery. 2023. DOI: 10.1097/iop.0000000000002480.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.