Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus.
Аннотация
INTRODUCTION
Traditional open reduction and internal fixation (ORIF) of extra-articular distal humerus fractures has a risk of iatrogenic radial nerve injury, extensive soft tissue stripping, and long incision scar. We performed an antero-lateral minimally invasive plate osteosynthesis (MIPO) technique with the radial nerve exploration for distal-third diaphyseal fractures of the humerus and evaluated clinical and radiographic outcomes through this respective study.
METHODS
From April 2010 to June 2016, 28 cases of extra-articular distal-third diaphyseal fractures were treated with an antero-lateral MIPO procedure. Patient demographics, Disabilities of the Arm, Shoulder and Hand (DASH) Score, Mayo Elbow Performance (MEP) Score, elbow range of motion, scars and post-operative complications were recorded and analyzed.
RESULTS
All fractures were united with a mean time of 3.5 months. One patient exhibited delayed union (3.6%). The mean DASH Score was 6.6, and all patients had excellent or good MEP Score values. The average scar length was 6.8 cm, and the shortest was 4.5 cm.
CONCLUSIONS
The MIPO technique via an antero-lateral approach for extra-articular distal-third diaphyseal fractures of the humerus results in satisfactory clinical outcomes.
LEVEL OF EVIDENCE: Level IV, case series, treatment study.