MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/02713680500320745

Медицинская библиотека · Current eye research · 2005

Staining and peeling of the internal limiting membrane in the cat eye.

Gandorfer Arnd, Rohleder Matthias, Charteris David G, Sethi Charanjit, Kampik Anselm, Luthert Philip

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the cat vitreomacular interface using trypan blue (TB) and indocyanine green (ICG) and to determine the validity of the cat model in terms of staining and peeling of the internal limiting membrane (ILM).

METHODS

Lensectomy and vitrectomy were performed in four eyes of two cats. The ILM of two eyes was stained with TB (0.15%). ILM peeling was performed in one eye. Two eyes were stained with ICG (0.5%). One eye was illuminated for 3 min. Light and transmission electron microscopy and confocal microscopy were performed.

RESULTS

Clinically, both dyes stained the cat ILM similar to human ILM. TB staining resulted in a normal ultrastructure and antigenity of the retina. ILM peeling was associated with intraretinal bleeding. There were fragments of Müller cells adherent to the retinal side of the ILM, and Müller cell endfeet were ruptured and avulsed. ICG staining of the ILM followed by illumination caused severe inner retinal damage. ICG without illumination resulted in focal ILM detachments associated with tearing of Müller cell endfeet.

CONCLUSIONS

The cat can be used as a model to study the effect of TB and ICG on the central area of the cat retina, as previous results from clinical and experimental postmortem settings in human eyes were confirmed in the current study. Peeling of the ILM as a sheet as performed in human macular surgery is not feasible. Differences in the ultrastructure of the ILM and a strong adhesion of the ILM to Müller cell endfeet may account for this observation.

Для цитирования: Gandorfer Arnd, Rohleder Matthias, Charteris David G, Sethi Charanjit, Kampik Anselm, Luthert Philip. Staining and peeling of the internal limiting membrane in the cat eye.. Current eye research. 2005. DOI: 10.1080/02713680500320745.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.