MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2023.07.022

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2024

Editorial Commentary: Shoulder Long Head of the Biceps Tendon Transposition Without Tenotomy May Be a Beneficial Augment for Massive Rotator Cuff Tear Repair.

Perry Nicholas P J, Smith Jennifer, Hurvitz Andrew, Baglien Peter, Nascimento Robert

Редакционная статьяКомментарийПеревод в очереди

Аннотация

Although many surgeons discard the long head of the biceps (LHB) tendon during arthroscopic rotator cuff repairs, several authors have argued that the LHB tendon may serve as a biologic and structural augment for massive repairs. There are multiple benefits of incorporating the LHB tendon autograft in difficult-to-repair massive rotator cuff tears. First, by maintaining the glenoid origin, the tendon likely retains a significant native blood supply, as well as tenocytes, which may support the healing process. In addition, there are several biomechanical benefits. The LHB may act as a dynamic humeral head depressor since it is still attached to the muscular unit distally. The tendon could also serve as a convergence post, while proving robust tissue for the repair. Also, the LHB tendon may decrease undue tension on the repair, bringing us closer to a tension-free repair. Finally, this may be a cost-conscious technique. One concern, requiring additional investigation, is that some surgeons believe the LHB may be a pain generator in patients with rotator cuff tears. One surgeon's trash is another surgeon's treasure.

Для цитирования: Perry Nicholas P J, Smith Jennifer, Hurvitz Andrew, Baglien Peter, Nascimento Robert. Editorial Commentary: Shoulder Long Head of the Biceps Tendon Transposition Without Tenotomy May Be a Beneficial Augment for Massive Rotator Cuff Tear Repair.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2024. DOI: 10.1016/j.arthro.2023.07.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.