Gatz Jennifer L, Armstrong Mary Anne, Postlethwaite Debbie, Raine-Bennett Tina, Chillemi Giulia, Alabaster Amy, Merchant Maqdooda, Reed Susan D, Ichikawa Laura, Getahun Darios, Fassett Michael J, Shi Jiaxiao M, Xie Fagen, Chiu Vicki Y, Im Theresa M, Takhar Harpreet S, Wang Jinyi, Saltus Catherine W, Ritchey Mary E, Asiimwe Alex, Pisa Federica, Schoendorf Juliane, Wahdan Yesmean, Zhou Xiaolei, Hunter Shannon, Anthony Mary S, Peipert Jeffrey F

Аннотация

BACKGROUND: Intrauterine devices, including levonorgestrel-releasing and copper devices, are highly effective long-acting reversible contraceptives. The potential risks associated with intrauterine devices are low and include uterine perforation and device expulsion.

OBJECTIVE: This study aimed to evaluate the risk of perforation and expulsion associated with levonorgestrel-releasing devices vs copper devices in clinical practice in the United States.

STUDY DESIGN: The Association of Perforation and Expulsion of Intrauterine Device study was a retrospective cohort study of women aged ≤50 years with an intrauterine device insertion during 2001 to 2018 and information on intrauterine device type and patient and medical characteristics. Of note, 4 research sites with access to electronic health records contributed data for the study: 3 Kaiser Permanente-integrated healthcare systems (Northern California, Southern California, and Washington) and 1 healthcare system using data from a healthcare information exchange in Indiana (Regenstrief Institute). Perforation was classified as any extension of the device into or through the myometrium. Expulsion was classified as complete (not visible in the uterus or abdomen or patient reported) or partial (any portion in the cervix or malpositioned). We estimated the crude incidence rates and crude cumulative incidence by intrauterine device type. The risks of perforation and expulsion associated with levonorgestrel-releasing intrauterine devices vs copper intrauterine devices were estimated using Cox proportional-hazards regression with propensity score overlap weighting to adjust for confounders.

RESULTS: Among 322,898 women included in this analysis, the incidence rates of perforation per 1000 person-years were 1.64 (95% confidence interval, 1.53-1.76) for levonorgestrel-releasing intrauterine devices and 1.27 (95% confidence interval, 1.08-1.48) for copper intrauterine devices; 1-year and 5-year crude cumulative incidence was 0.22% (95% confidence interval, 0.20-0.24) and 0.63% (95% confidence interval, 0.57-0.68) for levonorgestrel-releasing intrauterine devices and 0.16% (95% confidence interval, 0.13-0.20) and 0.55% (95% confidence interval, 0.44-0.68) for copper intrauterine devices, respectively. The incidence rates of expulsion per 1000 person-years were 13.95 (95% confidence interval, 13.63-14.28) for levonorgestrel-releasing intrauterine devices and 14.08 (95% confidence interval, 13.44-14.75) for copper intrauterine devices; 1-year and 5-year crude cumulative incidence was 2.30% (95% confidence interval, 2.24-2.36) and 4.52% (95% confidence interval, 4.40-4.65) for levonorgestrel-releasing intrauterine devices and 2.30% (95% confidence interval, 2.18-2.44) and 4.82 (95% confidence interval, 4.56-5.10) for copper intrauterine devices, respectively. Comparing levonorgestrel-releasing intrauterine devices with copper intrauterine devices, the adjusted hazard ratios were 1.49 (95% confidence intervals, 1.25-1.78) for perforation and 0.69 (95% confidence intervals, 0.65-0.73) for expulsion.

CONCLUSION: After adjusting for potential confounders, levonorgestrel-releasing intrauterine devices were associated with an increased risk of uterine perforation and a decreased risk of expulsion relative to copper intrauterine devices. Given that the absolute numbers of these events are low in both groups, these differences may not be clinically meaningful.