Reliability and reproducibility of classification of distal ulnar fractures using cone beam computed tomography (CBCT).

Wretö Linnéa, Fornander Lotta, Kämmerling Nina, Nyman Erika, Moloney Maria

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Distal ulnar fractures (DUFs) remain under-investigated, primarily due to limited statistical power resulting from the low incidence. The present classification systems are difficult to use and are not validated for new radiological methods such as cone beam computed tomography (CBCT). We aimed to analyze the reliability and reproducibility of the 2 classification systems, Arbeitsgemeinschaft für Osteosynthesefragen foundation/Orthopaedic Trauma Association (AO/OTA) and Biyani, for fractures of the distal ulnar head and neck using CBCT images.

METHODS

76 patients with DUF who underwent a CBCT scan during the years 2016-2022 were included retrospectively. The CBCT images were reviewed twice by 6 observers of different medical specialties and levels of experience. All fractures were classified according to AO/OTA and Biyani. The reliability and reproducibility of each classification system were analyzed using kappa value analysis.

RESULTS

The reliability was fair to moderate for AO/OTA, Light's ĸ 0.41 (95% confidence interval [CI] 0.38-0.45) and moderate for Biyani, Light's ĸ 0.45 (CI 0.42-0.49), and the reproducibility was substantial for both AO/OTA, mean ĸ 0.65 (CI 0.49-0.80), and Biyani, ĸ 0.69 (CI 0.60-0.79).

CONCLUSION

Both existing classification systems were perceived to be difficult to use and do not match existing fracture patterns. Using CBCT images, they both showed substantial reproducibility but not satisfactory reliability for clinical use.

Для цитирования: Wretö Linnéa, Fornander Lotta, Kämmerling Nina, Nyman Erika, Moloney Maria. Reliability and reproducibility of classification of distal ulnar fractures using cone beam computed tomography (CBCT).. Acta orthopaedica. 2026. DOI: 10.2340/17453674.2026.46344.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.