MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/sap.0000000000001653

Медицинская библиотека · Annals of plastic surgery · 2019

Distal Radius Fractures in the Elderly: Use of the Volar Bearing Plate.

Miller Jonathan E, Naram Aparajit, Qin BaiJing, Rothkopf Douglas M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Distal radius fractures represent some of the most common injuries to the upper extremity, yet current evidence demonstrates great variability in the management of this injury. Elderly patients, in particular, stand to benefit from the early mobilization provided by operative fixation with a volar bearing plate.

METHODS

We conducted a retrospective chart review on all patients 65 years or older who underwent unilateral open reduction internal fixation of distal radius fractures using a volar bearing plate at a single institution between January 2014 and January 2016. We excluded patients with bilateral injuries, multiple fractures, and major injuries to the same extremity.

RESULTS

Fifty-five patients met criteria for this study. By AO classification, we repaired 17 type A, 24 type B, and 14 type C fractures. At final radiographic measurements, average radial height compared with ulna measured -0.31 mm, average radial inclination measured 20.45 degrees, and average volar tilt measured 7.11 degrees. On discharge, 36 patients had wrist range-of-motion data consistent with a functional wrist. Four patients had limitations in the flexion/extension plane, 8 with radial-ulnar deviation, and 7 had limitations in both planes.

CONCLUSIONS

Distal radius fractures in the elderly may successfully be treated with a volar bearing plate. Useful strategies include supraperiosteal dissection of the radius from the pronator quadratus, use of a longer plate for stronger proximal fixation in osteoporotic bone, and regional block. This methodology allows for a safe procedure facilitating the early return of hand and wrist function.

Для цитирования: Miller Jonathan E, Naram Aparajit, Qin BaiJing, Rothkopf Douglas M. Distal Radius Fractures in the Elderly: Use of the Volar Bearing Plate.. Annals of plastic surgery. 2019. DOI: 10.1097/sap.0000000000001653.