MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3340/jkns.2010.47.1.7

Медицинская библиотека · Journal of Korean Neurosurgical Society · 2010

Intracranial pressure and experimental model of diffuse brain injury in rats.

Blaha Martin, Schwab Juraj, Vajnerova Olga, Bednar Michal, Vajner Ludek, Michal Tichy

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

In this study, we present a simple closed head injury model as a two-stage experiment. The height of the weight drop enables gradation of head trauma severity.

METHODS

The head injury device consists of three parts and there are three adjustable parameters-weight (100-600 g), height of fall (5-100 cm) and elasticity of the springs. Thirty male Wistar rats underwent monitoring of intracranial pressure with and without induction of the head injury.

RESULTS

The weight drop from 45 to 100 cm led to immediate seizure activity and early death of the experimental animals. Severe head injury was induced from 40 cm weight drop. There was 50% mortality and all surviving rats had behavioral deterioration. Intracranial pressure was 9.3 +/- 3.76 mmHg. Moderate head injury was induced from 35 cm, mortality decreased to 20-40%, only half of the animals showed behavioral pathology and intracranial pressure was 7.6 +/- 3.54 mmHg. Weight drop from 30 cm caused mild head injury without mortality and neurological deterioration. Intracranial pressure was slightly higher compared to sham group- 5.5 +/- 0.74 mmHg and 2.9 +/- 0.81 mmHg respectively.

CONCLUSION

This model is an eligible tool to create graded brain injury with stepwise intracranial pressure elevation.

Для цитирования: Blaha Martin, Schwab Juraj, Vajnerova Olga, Bednar Michal, Vajner Ludek, Michal Tichy. Intracranial pressure and experimental model of diffuse brain injury in rats.. Journal of Korean Neurosurgical Society. 2010. DOI: 10.3340/jkns.2010.47.1.7.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.