Reduced diameter spheres increases the risk of chest blow-induced ventricular fibrillation (commotio cordis).

Kalin John, Madias Christopher, Alsheikh-Ali Alawi A, Link Mark S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Sudden death due to low-energy blunt trauma to the precordium (commotio cordis) has been described with a variety of sporting objects. However, the risk of ventricular fibrillation (VF) relative to the shape of the impact object is not known.

OBJECTIVE

The objective of the current experiment is to test whether the impact object shape is a clinical variable that affects the risk for commotio cordis.

METHODS

In a juvenile swine model, impacts were given in random order with two different spherical shapes (72 mm diameter, equivalent to a baseball; 42 mm diameter, equivalent to a golf ball) and a flat round object 72 mm in diameter. Objects were equal in weight (150 g), thrown at 30 mph, and gated to the vulnerable portion of the cardiac cycle.

RESULTS

Sixteen swine received 144 impacts. The flat object did not cause VF (P = .01 compared with the two spherical objects), nonsustained VF, ST elevation, or bundle branch block. The smaller diameter sphere caused VF in nine of 48 impacts (19%), and the larger diameter sphere caused VF in five of 48 impacts (10%; P = .25). The smaller diameter sphere was associated with a greater increase in left ventricular pressure (P <.0001 and P = .001 compared with larger sphere only) and a higher likelihood of ST segment elevations (P <.001 and P = .08 compared with larger sphere only) and bundle branch block (Fisher's exact P = .008, and Fisher's exact P = .18 compared with larger sphere only).

CONCLUSION

The shape of the projectile markedly influences the risk of VF from chest wall impact. This effect is likely mediated via a greater increase in left ventricular pressure with smaller diameter objects. Spreading the impact force over a larger area may decrease the risk of sudden death and has implications for the design of protective athletic equipment.

Для цитирования: Kalin John, Madias Christopher, Alsheikh-Ali Alawi A, Link Mark S. Reduced diameter spheres increases the risk of chest blow-induced ventricular fibrillation (commotio cordis).. Heart rhythm. 2011. DOI: 10.1016/j.hrthm.2011.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.