Медицинская библиотека · The Journal of the American Association of Gynecologic Laparoscopists · 2002

A randomized, multicenter trial of safety and efficacy of the NovaSure system in the treatment of menorrhagia.

Cooper Jay, Gimpelson Richard, Laberge Philippe, Galen Donald, Garza-Leal Jose Gerardo, Scott Josef, Leyland Nicholas, Martyn Paul, Liu James

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

OBJECTIVE

To compare the safety and effectiveness of the NovaSure impedance-controlled endometrial ablation system with hysteroscopic wire loop resection plus rollerball ablation for treatment of excessive uterine bleeding in premenopausal women.

DESIGN

Randomized, multicenter, double-arm study (Canadian Task Force classification I).

SETTING

Nine academic medical centers and private offices.

PATIENTS: Two hundred sixty-five premenopausal women with symptomatic menorrhagia.

INTERVENTION: Ablation performed with the NovaSure system or wire loop resection and rollerball.

MEASUREMENTS AND MAIN

RESULTS

Success [pictorial blood loss-assessment chart (PBLAC) score < or =75] was achieved in 88.3% of NovaSure-treated and 81.7% of rollerball-treated patients. One year after treatment 90.9% and 87.8%, respectively, reported normal bleeding or less (PBLAC < or =100) and 41% and 35%, respectively, experienced amenorrhea (PBLAC = 0). Mean procedure time was 4.2 minutes (average 84 sec) in the NovaSure group and 24.2 minutes in the rollerball group. Local and/or intravenous sedation was administered in 73% of NovaSure patients and 18% of rollerball patients. Intraoperative adverse events occurred less frequently with NovaSure (0.6%) than with rollerball (6.7%). Postoperative adverse events occurred in 13% and 25.3% of patients, respectively.

CONCLUSION

The NovaSure system was safe and effective in treatment of women with menorrhagia. The procedure is both quick and effective, and eliminates the expense and side effects of endometrial pretreatment.

Для цитирования: Cooper Jay, Gimpelson Richard, Laberge Philippe, Galen Donald, Garza-Leal Jose Gerardo, Scott Josef, Leyland Nicholas, Martyn Paul, Liu James. A randomized, multicenter trial of safety and efficacy of the NovaSure system in the treatment of menorrhagia.. The Journal of the American Association of Gynecologic Laparoscopists. 2002. DOI: 10.1016/s1074-3804(05)60513-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.