Computer tomographic analysis of anatomic characteristics of the ulna - essential parameters for preshaped implants.

Hopf Johannes Christof, Jähnig Andreas, Jorg Tobias, Westphal Ruben Sebastian, Wagner Daniel, Rommens Pol Maria

СтатьяПеревод в очереди

Аннотация

PURPOSE: Anatomically preshaped implants are needed for exact restoration of the anatomy after fractures of the proximal ulna and ulnar shaft, which enables a good functional outcome. Aim of this computed tomographic analysis was to identify specific characteristics of the ulna. The data serve for the development of a new intramedullary implant for stabilisation of proximal and diaphyseal ulna fractures.

METHODS

With a standardized research method 100 CT scans of the ulna were evaluated regarding anatomic parameters like width of the medullary canal, proximal ulna dorsal angulation and varus angulation. Also, correlations of these parameters were analyzed statistically.

RESULTS

The mean proximal ulna dorsal angulation (PUDA) was 6.4° (SD 2.8°), while the mean varus angulation of the proximal ulna was 12.4° (SD 3.3°). The length of the ulna bone was 253.6 mm (SD 19.9 mm) on average. The average minimum diameter of the medullary canal was 4.2 mm (SD 1.1 mm) located at 141.3 mm (SD 19.7 mm) from the olecranon tip. There is a positive correlation between age and minimum diameter in our patient cohort (p< 0.001).

CONCLUSION

Our study described the anatomy of the proximal ulna and the ulna shaft with a reproducible research method in a representative patient cohort. The knowledge of the evaluated anatomic parameters can lead to an improvement of any implant design for the fixation of proximal and diaphyseal ulna fractures.

Для цитирования: Hopf Johannes Christof, Jähnig Andreas, Jorg Tobias, Westphal Ruben Sebastian, Wagner Daniel, Rommens Pol Maria. Computer tomographic analysis of anatomic characteristics of the ulna - essential parameters for preshaped implants.. PloS one. 2020. DOI: 10.1371/journal.pone.0232988.