DOI 10.1097/j.jcrs.0000000000001141
Efficacy and safety of the eight-chop technique in phacoemulsification for patients with cataract.
Аннотация
PURPOSE: The aim of this study was to estimate the efficacy of the 8-chop technique in phacoemulsification surgeries of patients with cataract.
SETTING
Sato Eye Clinic, Chiba-ken, Japan.
DESIGN
Prospective study.
METHODS
Patients were classified into 3 groups (Grade II, Grade III, and Grade IV; n = 50 each) according to the firmness of their lens nuclei. The Eight-chopper I was used for Grade II, Eight-chopper II for Grade III, and Lance-chopper for Grade IV. The best-corrected visual acuity, intraocular pressure (IOP), and endothelial cell density were evaluated at 7 and 19 weeks postoperatively. The primary outcome measures were the mean operative time, mean phaco time, cumulative dissipated energy (CDE), and volume of fluid used.
RESULTS
150 cataract surgeries were performed. The operative time (minutes), phaco time (seconds), CDE, and volume of fluid used (milliliters) differed significantly among the 3 groups, increasing in the following order: Grade II, Grade III, and Grade IV ( P < .01). The corneal endothelial cell density did not decrease significantly in the 3 groups at 19 weeks postoperatively ( P = .09). The rate of endothelial cell loss was 0.9% ± 5.9%, 1.0% ± 10.3%, and 5.3% ± 11.1% in the Grade II, III, and IV groups at 19 weeks postoperatively, respectively. There were significant reductions in the IOP at 7 and 19 weeks postoperatively compared with the preoperative IOP in the 3 groups ( P < .01).
CONCLUSIONS
The 8-chop technique was effective and safe in phacoemulsification for patients with cataracts with lens nuclei of varying hardness.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.