Strategies to Reduce Errors Associated with 2-Component Vaccines.

Samad Farzana, Burton Samantha J, Kwan Diana, Porter Noah, Smetzer Judy, Cohen Michael R, Tuttle Jeanne, Baker Danial, Doherty Dennis E

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The high incidence of error reports received by the US Food and Drug Administration (FDA) involving 2-component vaccines led to collaboration between the United States Pharmacopeia (USP) and the Institute for Safe Medication Practices (ISMP). This collaborating group sought to further understand errors associated with all 2-component vaccines (i.e. vaccine components provided by the manufacturer in physically separate containers) and to provide safe practice strategies for storing, preparing, dispensing, and administering these vaccines as intended. Fourteen available 2-component vaccines were identified. The ISMP National Vaccine Errors Reporting Program (VERP) and the FDA Vaccine Adverse Event Reporting System (VAERS) were searched from the initiation of each respective reporting system through December 31, 2019. The three vaccines with the most reported reconstitution errors in the VERP and VAERS are Menveo® (meningococcal), Pentacel® (DTaP, Polio, Haemophilus influenzae type b), and ActHIB® [H. influenzae type b (Hib)]. Manufacturers should design labeling and packaging of vaccines to provide ease of storage and fail-safe preparation to prevent 2-component vaccine errors. Implementing risk reduction strategies, such as training healthcare professionals and affixing storage bin labels, remind healthcare professionals to mix the 2-components and facilitate appropriate administration.

Для цитирования: Samad Farzana, Burton Samantha J, Kwan Diana, Porter Noah, Smetzer Judy, Cohen Michael R, Tuttle Jeanne, Baker Danial, Doherty Dennis E. Strategies to Reduce Errors Associated with 2-Component Vaccines.. Pharmaceutical medicine. 2020. DOI: 10.1007/s40290-020-00362-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.