MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-022-04655-3

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2022

A double tapered fully hydroxyapatite-coated stem has less contact area to femoral cortical bone than a tapered-wedge stem: a three-dimensional computed tomography-based density mapping analysis.

Ohyama Yohei, Minoda Yukihide, Ohta Yoichi, Sugama Ryo, Takemura Susumu, Nakamura Hiroaki

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

It is clinically important to analyze the initial contact state between an implant and femoral cortical bone as it affects clinical outcomes, such as stress shielding, stem subsidence, thigh pain, and patient-reported outcomes after total hip arthroplasty. Whether the initial contact state of a double-tapered fully hydroxyapatite (HA)-coated stem is achieved with the preserved cancellous or cortical bone remains to be established. This study aimed to compare the contact area with the femoral cortical bone between a double-tapered fully HA-coated stem (HA group) and a tapered wedge cementless stem (TW group) using three-dimensional computed tomography (3DCT)-based templating software.

MATERIALS AND

METHODS

Forty-seven total hip arthroplasties in the HA and TW groups each were retrospectively analyzed. The contact area between the implant and femoral cortical bone in the whole stem and at each Gruen zone was measured using density mapping with 3DCT-based templating software.

RESULTS

The demographic data were not significantly different between the two groups. The contact area in the whole stem area was lower in the HA group (HA 5.4 ± 1.8% vs. TW 9.0 ± 4.8%, p < 0.01). The HA group had a lower contact area in zone 2 (HA 6.7 ± 6.5% vs. TW 15.6 ± 10.8%, p < 0.01) and zone 6 (HA 1.8 ± 3.5% vs. TW 6.3 ± 3.6%, p < 0.01) than the TW group. The implant type (β = 0.41, p < 0.01) and stem coronal alignment (β = - 0.29, p < 0.01) were significant predictors of the contact area in the whole stem area in a multiple regression analysis (adjusted R2 = 0.27, p < 0.01).

CONCLUSION

The contact area of the double-tapered fully HA-coated stem was significantly lower than that of the tapered wedge cementless stem.

Для цитирования: Ohyama Yohei, Minoda Yukihide, Ohta Yoichi, Sugama Ryo, Takemura Susumu, Nakamura Hiroaki. A double tapered fully hydroxyapatite-coated stem has less contact area to femoral cortical bone than a tapered-wedge stem: a three-dimensional computed tomography-based density mapping analysis.. Archives of orthopaedic and trauma surgery. 2022. DOI: 10.1007/s00402-022-04655-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.