Intra-SVC re-entrant atrial tachycardia successfully treated with a circular multi-electrode array pulsed-field ablation catheter-case report.

Ikenaga Takeru, Nozoe Masatsugu, Mannoji Hiroshi, Suematsu Nobuhiro, Kubota Toru

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

The superior vena cava (SVC) is a well-recognized non-pulmonary vein (PV) focus in atrial fibrillation (AF); however, intra-SVC re-entrant atrial tachycardia (AT) is extremely rare.

CASE SUMMARY: An 83-year-old woman with a history of PV isolation using radiofrequency ablation 1 year earlier was referred for a second ablation due to recurrent AT. Activation mapping of the AT demonstrated a re-entrant circuit involving the left atrial (LA) posterior wall. Because bilateral PVs were reconnected, pulsed-field ablation (PFA), including PV re-isolation and LA posterior wall isolation, was performed using a circular multi-electrode array PFA catheter. The initial PFA application did not terminate the tachycardia; however, the arrhythmia transitioned to a different AT. High-resolution mapping revealed a re-entrant circuit confined within the SVC sleeves, characterized by transverse re-entrant propagation. Entrainment pacing confirmed intra-SVC re-entry. Circumferential PFA was delivered to the SVC during sinus rhythm, achieving SVC isolation without sinus node dysfunction or phrenic nerve palsy.

DISCUSSION: This case demonstrates effective management of intra-SVC re-entrant AT using a circular multi-electrode PFA catheter. High-resolution mapping identified a rare re-entrant circuit confined to the SVC. Owing to its tissue selectivity, PFA enables safe and effective SVC isolation while minimizing the risk of phrenic nerve injury.

Для цитирования: Ikenaga Takeru, Nozoe Masatsugu, Mannoji Hiroshi, Suematsu Nobuhiro, Kubota Toru. Intra-SVC re-entrant atrial tachycardia successfully treated with a circular multi-electrode array pulsed-field ablation catheter-case report.. European heart journal. Case reports. 2026. DOI: 10.1093/ehjcr/ytag478.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.