Аннотация

BACKGROUND

Asherman's syndrome, or intrauterine synechiae, is characterized by partial or complete obliteration of the uterine cavity and/or the cervical canal. In order to preserve the integrity of the uterine cavity after correction, placement of an intrauterine Foley catheter with the balloon inflated is routinely performed.

CASE: We report a case of uterine rupture and intraperitoneal bleeding presumably related to the pressure of the intrauterine balloon following hysteroscopic lysis of adhesions.

CONCLUSION

We conclude that uterine rupture can occur because of intrauterine expansion of a Foley balloon after hysteroscopic treatment of intrauterine synechiae.

Для цитирования: Goorah Berenice, Tulandi Togas. Uterine rupture resulting from the pressure of an intrauterine balloon.. Journal of obstetrics and gynaecology Canada : JOGC = Journal d'obstetrique et gynecologie du Canada : JOGC. 2009. DOI: 10.1016/s1701-2163(16)34244-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.