m+Medelevator.RU
← Поиск публикаций
Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons · 2024

Ultrasound-guided injection of the achilles paratenon: A cadaveric investigation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ricci Vincenzo, Mezian Kamal, Chang Ke-Vin, Tamborrini Giorgio, Jačisko Jakub, Naňka Ondřej, Özçakar Levent

Аннотация

BACKGROUND: Injections around the Achilles tendon (AT) are commonly performed in clinical practice to manage non-insertional Achilles tendinopathy, but the presence/distribution of the injectate with relation to its sheath has not been assessed specifically. Accordingly, the aim of this cadaveric investigation was to demonstrate the feasibility of Achilles paratenon injection under ultrasound guidance - by confirming the exact needle positioning as well as the dye distribution inside the paratenon lumen.

METHODS: A descriptive laboratory study with three human cadaveric specimens (one fresh cadaver and two cadavers embalmed using the Fix for Life (F4L) method) was performed in a tertiary-care academic institution. The interventional technique and the related anatomical findings were illustrated. During the injection, the needle was advanced inside the Achilles paratenon under ultrasound guidance i.e. in-plane medial-to-lateral approach. With the objective to confirm its correct placement, the needle was kept in situ on the right AT of the fresh cadaver. Likewise, to demonstrate the location of the dye inside the lumen of Achilles paratenon, the other five ATs - four on the embalmed cadavers and one on the fresh cadaver - were injected with 5 mL of green color dye. After removal of the needle, a layer-by-layer anatomical dissection was performed on all three cadavers.

RESULTS: On the right AT of the fresh cadaver, the position of the needle's tip within the Achilles paratenon was confirmed. Accurate placement of the dye inside the paratenon lumen was confirmed in four (80%) ATs, one of the fresh and three of the embalmed cadavers. No spread inside the crural fascia compartment or between the AT and the Kager's fat pad was observed. Herewith, unintentional spilling of the dye within the superficial soft tissues of the posterior leg was reported in the left AT of one of the two embalmed cadavers (20%).

CONCLUSIONS: Ultrasound-guided injection using the in-plane, medial-to-lateral approach can accurately target the lumen of Achilles paratenon.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты