Аннотация

PURPOSE: Fracture union after osteosynthesis of a fracture neck femur (FNF) occurs by compression of the fracture ends and potential neck shortening. Selection of an implant for fixation of a femoral fracture of the neck can be challenging when making management decisions. Femoral neck shortening after internal fixation of FNFs using a femoral neck system (FNS) or multiple cannulated cancellous screws (MCS) was compared.

MATERIALS AND

METHODS

This prospective interventional single-blinded randomized controlled trial was conducted at a university teaching hospital. Sixty patients undergoing internal fixation for management of sub-capital or trans-cervical FNFs were randomized and assigned, to one of the two groups-the test group (FNS group) and the control group (MCS group). Primary outcome was determined by measuring the difference in 1-year shortening of the femoral neck on radiographs between FNS and MCS. The secondary objective was to determine the correlation between neck shortening with patient reported outcome measures (PROMs) at the end of the final follow-up.

RESULTS

At the final follow-up, shortening of the femoral neck was 3.77±1.87 mm in the FNS group, significantly lower compared with the MCS group, 6.53±1.59 mm.

CONCLUSION

Significantly less shortening of the femoral neck was observed in the FNS group compared with the MCS group. No statistically significant difference in PROMs was observed at 1-year follow-up. The findings of the study suggest that FNS can be regarded as a suitable alternative for internal fixation in young adults (<60 years) with trans-cervical and subcapital FNFs.

Для цитирования: Gupta Saurabh, Elhence Abhay, Banerjee Sumit, Yadav Sandeep, Kantiwal Prabodh, Rajnish Rajesh Kumar, Khera Pushpinder, Malhotra Rajesh. Difference of Neck Shortening in Femoral Neck Fracture between Femoral Neck System and Multiple Cannulated Cancellous Screws: Single Center, Prospective Randomized Controlled Trial.. Hip & pelvis. 2024. DOI: 10.5371/hp.2024.36.4.310.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.