DOI 10.11005/jbm.2020.27.4.261
The 2nd Metacarpal Cortical Index as a Simple Screening Tool for Osteopenia.
Аннотация
BACKGROUND
Osteopenia is a known risk factor for sustaining skeletal fractures. Prevention of fragility fractures has obvious clinical and economic advantages, however screening all patients using a dual energy X-ray absorptiometry (DXA) is controversial not only because of the cost implications but also because it would potentially involve exposing a percentage of normal patients to unnecessary radiation. We wished to assess whether a simple hand X-ray measuring the 2nd metacarpal cortical index (2MCI) could be used as a simple screening tool for identifying patients with osteopenia.
METHODS
We retrospectively collected the radiographic data of 206 patients who had a simple radiograph of the hand and a DXA scan within one year of each other from our picture archiving and communication system database. The 2MCI was calculated for all patients. As data was parametric, a Pearson's correlation was performed to assess association between Tscores and 2MCI. Further analysis involved the construction of receiver operating characteristic (ROC) curves to identify a 2MCI index, which would give the most appropriate sensitivity and specificity values for identifying the presence of osteopenia.
RESULTS
A statistically significant and moderate correlation between DXA T-scores and 2MCI values was found (r=0.54, n=206, P<0.001). Further ROC curve analysis of normal and osteopenic subjects identified that a 2MCI of 41.5 had a sensitivity of 100% and specificity of 53% for detecting osteopenia.
CONCLUSIONS
Our results support the use of the 2MCI as a simple screening tool for identifying patients with osteopenia.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.