MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0000000000001679

Медицинская библиотека · Journal of orthopaedic trauma · 2020

Comparison of Locked Plating of Varus Displaced Proximal Humeral Fractures With and Without Fibula Allograft Augmentation.

Davids Stephen, Allen Dexter, Desarno Michael, Endres Nathan K, Bartlett Craig, Shafritz Adam

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare the clinical and radiographic outcomes between patients treated with fibula allograft-augmented locking compression fixation and patients treated with locking compression fixation alone for 2- and 3-part proximal humeral fractures with varus displacement.

DESIGN

Retrospective review.

SETTING

Level 1 trauma center.

PATIENTS/

PARTICIPANTS

One hundred two patients treated with locking plate fixation ± fibular allograft augmentation confirmed intraoperatively by visual inspection to have varus-angulated, 2- and 3-part proximal humerus fractures with at least 45 degrees of varus angulation at the neck/shaft and at least 1 cm of displacement.

INTERVENTION: Proximal humerus locking plate (PHILOS; Synthes, Paoli, PA) with or without fibula allograft augmentation.

MAIN OUTCOME MEASUREMENTS: Statistical analysis to determine the differences between fractures treated with locking compression fixation ± fibula allograft augmentation regarding complications, shoulder reported outcome measures, and patient ROMs (Visual Analog Score (VAS), Disabilities of the Arm, Shoulder and Hand, and Simple Shoulder Test scores). Medical comorbidities as potential risk factors for complication from surgery were also evaluated.

RESULTS

Of 102 surgical cases, 27 were augmented with fibula allograft and 75 were not. Postoperatively, there were 16 noncatastrophic varus collapses of the fracture, 6 catastrophic varus collapses, and 5 deaths. Addition of fibula allograft did not significantly affect postoperative varus collapse, shoulder ROM, pain, or PROMs.

CONCLUSION

Addition of fibula allograft to patients sustaining varus-angulated, 2- and 3-part proximal humeral fractures conferred no benefit to patient outcomes at our institution.

LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Davids Stephen, Allen Dexter, Desarno Michael, Endres Nathan K, Bartlett Craig, Shafritz Adam. Comparison of Locked Plating of Varus Displaced Proximal Humeral Fractures With and Without Fibula Allograft Augmentation.. Journal of orthopaedic trauma. 2020. DOI: 10.1097/bot.0000000000001679.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.