BACKGROUND

Chronic Achilles tendon ruptures are associated with considerable functional morbidity. When treated operatively, debridement of degenerated tendon ends may create large defects. Various procedures to reconstruct large defects have been described. We present a simple technique in which an autologous semitendinosus tendon graft is used to reconstruct defects larger than 5 cm in chronic Achilles tendon ruptures. The purpose of this study was to describe our operative technique and its functional outcome.

METHODS

Achilles ruptures of more than 6 weeks duration were considered for the study. We treated 35 patients (20 males, 15 females) with symptomatic chronic Achilles tendon ruptures. The mean age was 47.4 years (range, 30 to 59). The smallest defect that we had reconstructed was 5 cm, and the largest was 9 cm in length. The average follow-up duration was 30.7 months (range, 20 to 42). Postoperatively, the strength of gastrocsoleus was measured by manual muscle testing (MMT) in non-weight-bearing and weight-bearing positions.

RESULTS

All operated patients showed satisfactory functional outcome, good soft tissue healing, and no reruptures. The preoperative weight-bearing MMT of 2/5 improved to 4/5 or 5/5 postoperatively. In all patients, postoperative non-weight-bearing MMT was 5/5. All patients returned to their prerupture daily activity.

CONCLUSION

We present a technique that is simple, with low morbidity. We believe it is a valuable option especially when allografts are not available. It is inexpensive as suture anchors or tenodesis screws are not used. This can be a useful option if other tendons (flexor hallucis longus, peroneus brevis, etc) are not available for transfer.

LEVEL OF EVIDENCE: Level IV, retrospective case series.

Для цитирования: Dumbre Patil Sampat Shivajirao, Dumbre Patil Vaishali Sampat, Basa Vikas Rajeshwarrao, Dombale Ajay Birappa. Semitendinosus Tendon Autograft for Reconstruction of Large Defects in Chronic Achilles Tendon Ruptures.. Foot & ankle international. 2014. DOI: 10.1177/1071100714531228.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.