m+Medelevator.RU
← Поиск публикаций
BMC musculoskeletal disorders · 2023

Subtrochanteric fracture after femoral neck system of femoral neck fractures: a report of four cases.

Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Fisher John C, Gerzina Christopher, Rush Kaitlin, Caroom Cyrus

Аннотация

BACKGROUND: The femoral neck system (FNS) is commonly used for internal fixation of femoral neck fractures and has shown promising results. However, we have observed cases of peri-implant subtrochanteric femur fractures associated with the use of FNS at our institution. This case series aims to investigate four cases of peri-implant subtrochanteric fractures in patients treated with the FNS implant for femoral neck fractures.

CASE PRESENTATION: We reviewed 35 patients who underwent treatment with FNS for femoral neck fractures between January 2017 and December 2021 at our level 1 trauma institution. Among these patients, four cases of peri-implant subtrochanteric femur fractures were identified. In contrast, no such fractures occurred in patients treated with cannulated screws or dynamic hip screws (DHS). Interestingly, all four cases of peri-implant fractures were seen in patients with incomplete nondisplaced femoral neck fractures. Only one case involved an identifiable technical error.

CONCLUSIONS: This case series sheds light on peri-implant subtrochanteric femur fractures as a previously unreported complication associated with the use of FNS for femoral neck fractures. These fractures were observed exclusively in patients with incomplete nondisplaced fractures who received FNS fixation. No similar complications were observed in patients treated with other types of fixation. This finding suggests the need for caution and further investigation when considering FNS as a treatment option for this specific fracture pattern. The identification of peri-implant subtrochanteric femur fractures as a potential complication of FNS usage in incomplete nondisplaced femoral neck fractures raises important considerations for clinical decision-making and patient management in orthopedic trauma.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты